Web Manager for OnSite Administrators 265
Configuration>Serial/AUX>Aux/Modem Port
Hn
Hook control.
n = 0 or 1
Default: 0
H0 – Go on-hook (hang up).
H1 – Go off-hook (make the phone line busy).
Mn
Monitor speaker mode.
n = 0, 1, 2, or 3
Default: 1
M0 – Speaker always off.
M1 – Speaker on until carrier signal detected.
M2 – Speaker always on when modem is off-hook.
M3 – Speaker on until carrier is detected, except while dialing.
Vn
Result code format.
n = 0, 1, or 2
Default: 1
V0 – displays result codes as digits (terse response).
V1 – Displays result codes as words (verbose response).
Z
Modem reset.
Resets modem to profile saved by the last &W command.
&F
Load factory settings as active configuration.
Table 6-20: Commonly-Used Supported AT Commands (Sheet 3 of 4)