Changing Web Manager Timeouts
102 AlterPath OnBoard Administrator’s Guide
4. Add the pathname of the new file to the list.
5. Save and quit the file.
Changing Web Manager Timeouts
An OnBoard adminsitrator can manually change the timeout value for Web
Manager logins by editing a configuration file. The default timeout value is
1800 seconds (30 minutes). The value can be changed to any number of
seconds up to 2
13
, which would disable timeouts up to sixty years.
T To Disable Web Manager Timeouts
1. Connect to the OnBoard’s console and log in as root.
2. Change to the /etc/cacpd directory and open the cacpd.conf file
for editing.
3. Find the following lines:
4. Change the timeout value to the desired number of seconds.
5. Save and quit the file.
/etc/ypbind.conf
/etc/yp.conf
/etc/localtime
/etc/timezone
/pathname/to/new/file
:wq
config{
timeout: 1800
}
Zobrazit stránku 141